| fault |
Possible reasons |
Troubleshooting methods |
|
| No liquid flow |
Liquid pressure too low |
Increase the liquid pressure of the liquid storage device |
|
| The operating pressure is too low |
Increase the air pressure of the valve controller |
||
| Needle blockage or damage |
Replace the needle |
||
| Liquid solidifies inside the valve chamber |
Remove the valve and thoroughly clean it |
||
| Turn off the adjustment switch |
Turn on the adjustment switch counterclockwise |
||
| Unstable liquid flow |
Unstable liquid pressure |
Ensure a constant liquid pressure |
|
| The operating pressure of the valve is too low |
Raise the valve operating pressure of the valve controller |
||
| The opening time of the valve is inconsistent |
Check the valve controller to ensure it provides stability |
||
| Gas is trapped in the valve cover |
Discharge gas from the valve |
||
| After the valve is closed, liquid still drips out and stops after a period of time |
Gas is trapped in the liquid shield |
Discharge gas from the valve |
|
| Unstable droplets |
Dirty needles and valve seats |
Thoroughly clean |
|
| Worn needles and valve seats |
Replace worn or damaged parts |
||
| Fluid pressure exceeds300 psi(20.7bar) |
Lower fluid pressure |
||
| The assembly sequence of the valve body is incorrect |
Reassemble the valve body |