Common faults and solutions of Techcon TS5420 needle valve

Release Date:2017-09-25

Common faults and solutions of Techcon TS5420 needle valve

fault

Possible reasons

Troubleshooting methods

No liquid flow

Liquid pressure too low

Increase the liquid pressure of the liquid storage device

The operating pressure is too low

Increase the air pressure of the valve controller
reach70 psi (4.8 bar)

Needle blockage or damage

Replace the needle

Liquid solidifies inside the valve chamber

Remove the valve and thoroughly clean it

Turn off the adjustment switch

Turn on the adjustment switch counterclockwise

Unstable liquid flow

Unstable liquid pressure

Ensure a constant liquid pressure

The operating pressure of the valve is too low

Raise the valve operating pressure of the valve controller
High to70 psi (4.8 bar)

The opening time of the valve is inconsistent

Check the valve controller to ensure it provides stability
Fixed air pressure output

Gas is trapped in the valve cover

Discharge gas from the valve

After the valve is closed, liquid still drips out and stops after a period of time

Gas is trapped in the liquid shield

Discharge gas from the valve

Unstable droplets

Dirty needles and valve seats

Thoroughly clean

Worn needles and valve seats

Replace worn or damaged parts

Fluid pressure exceeds300 psi(20.7bar)

Lower fluid pressure

The assembly sequence of the valve body is incorrect

Reassemble the valve body